Table 3:

Mean percent difference [95% confidence intervals for mean percent difference] in personal exposure in each microenvironment compared to the Home microenvironment.

N Home Work Transit Eatery Other
BC 1310 Ref. −1
[−13, 14]
129
[101, 162]
93
[58, 137]
24
[8, 44]
PM2.5 1158 Ref. −70
[−74, −66]
-14
[−25, −1]
8
[−13, 33]
−39
[−47, −29]
CO 1354 Ref. −57
[−62, −52]
51
[34, 70]
8
[−11, 30]
−22
[−32, −11]
PNC 468 Ref. −67
[−74, −59]
32
[6, 64]
180
[101, 289]
−11
[−30, 13]