Table 1.

Initial Stiffness, Displacement With Cyclic Loading, Final Stiffness, Load to Failure, and Displacement at Failure of the HCS, KW, and LP Models.

Variables tested HCS KW LP
Displacement after cyclic loading, mm 2.5 ± 0.1 2.8 ± 0.5 0.2 ± 1.0
Stiffness, N/m 7.3 ± 0.7 5.8 ± 0.5 9.5 ± 1.9
Load to failure, N 215.5 ± 39.0 279.7 ± 100.3 267.9 ± 44.1
Displacement to failure, mm 8.7 ± 2.5 6.6 ± 2.8 3.6 ± 0.2