Skip to main content
. Author manuscript; available in PMC: 2019 Oct 1.
Published in final edited form as: IEEE Sens J. 2018 Aug 6;18(19):7899–7906. doi: 10.1109/JSEN.2018.2863644

Fig. 7.

Fig. 7.

The R2rop output voltage range and linearity error as a function of input voltage. The absolute error of the output voltage is less than 0.05% over the range from 0.03 V to 4.90 V.