Skip to main content
. 2019 Mar 12;12(3):e227892. doi: 10.1136/bcr-2018-227892

Table 1.

Ventilator modes at different time

Time Mode TV set TV delivered PEEP Plateau PIP FiO2 RR/min P/F SpO2
T (−2) VCV 300 240–280 12–14 34–37 45–50 100 24 54 72%
T (−1) VCV 320 300–320 14–20 32–34 45 100 24 55 71%–75%
T0 VCV 350 300–350 20 32–34 43 100 24 71%–75%
T4hr VCV 360 350–400 18 30–34 40 60 22 131 92%
T8hr VCV 360 360–400 16 28–30 35 60 22 99%
T16 hr VCV 400 400 16 25–30 35 55 20 257 99%

(T (−2) before sedation and paralysis, T (−1) after 4 hours of sedation and paralysis. T0- immediately after proning, T4h, T8hr, T16hr- corresponding hour after proning). FiO2, fraction of inspired oxygen; PEEP, positive end expiratory pressure; PIP, peak inspiratory pressure; P/F, PaO2/Fio2; RR, respiratory rate; SpO2-peripheral oxygen saturation; TV, tidal volume; VCV, volume control ventilation.