Skip to main content
. 2019 Apr 2;8(4):418–428. doi: 10.1002/open.201900004

Table 4.

Table of gravimetric capacitances before and after cycling for all graphene materials calculated from both CV and GCD at two scan rates and current densities. Note for the rGO electrodes it was not possible to calculate the capacitance from the GCD after cycling as the discharge curve was dominated by the iR drop.

Material

Before Cycling

CV capacitance [F  g−1]

GCD Capacitance [F  g−1]

10 mV s−1

100 mV s−1

0.5 A g−1

2 A g−1

GO

164.6±3.2

59.2±2.1

153.7±1.6

10.9±0.8

rGO

137.4±3.3

41.3±1.2

119.6±2.6

49.4±1.9

LEG

14.8±0.7

13.4±0.8

14.5±0.4

12.7±0.5

CEEG

32.8±0.9

29.8±1.1

22.4±0.7

20.1±0.6

AEEG

44.0±1.4

42.8±1.9

46.7±1.0

40.8±0.7

GNR

11.4±0.5

9.7±0.5

12.4±0.6

11.5±0.9

Material

After Cycling

CV Capacitance [F  g−1]

GCD Capacitance [F  g−1]

10 mV s−1

100 mV s−1

0.5 A g−1

2 A g−1

GO

166.4±2.7

62.1±2.3

181.5±1.5

15.7±0.9

rGO

81.2±2.3

31.9±1.8

N/A

N/A

LEG

14.9±0.7

12.4±0.8

22.2±1.0

17.9±1.2

CEEG

29.2±1.1

26.5 ±1.0

27.9±0.6

25.9±0.8

AEEG

44.6±1.1

42.3±1.2

47.8±1.0

42.8±0.9

GNR

14.1±0.8

11.7±0.7

15.7±0.7

14.6±0.6