Skip to main content
. 2019 Apr 2;9:5531. doi: 10.1038/s41598-019-41722-z

Table 2.

Assay performance of the duplex-assay for detection of BoNT/A-F substrate cleavage.

BoNT/A BoNT/B BoNT/C BoNT/D BoNT/E BoNT/F
EC50 (pg/mL) 70 47 18901 16 654c 17
LOD (pg/mL) 0.8 1.2 79.1 1.1 13 0.3
(95% CI)a (0.6–1.3) (0.7–5.4) (45–227) (0.9–1.3) (9.2–23.7) (0.2–0.4)
LOD (LD50/mL)b 0.211 0.147 2.056 0.18d 0.84 0.005

aCutoff: mean + 3.29 × SD of blank values (determined with 36 blank values for each serotype) including lower and upper limit of 95% confidence interval (CI; shown in parentheses). bLimit of detection (LOD) in mouse minimal lethal doses (LD50/mL) according to toxin activity as specified by the manufacturer (see Methods). ctrypsinated BoNT/E. dCalculated according to Sugiyama35.