Table 3.

Test-retest reliability for Optokinetic Reflex and Reaction Times (n=40-43). Optokinetic gain is defined as fast phase eye velocity / optokinetic stimulus velocity.

*Optokinetic Gain Test 1
Mean ± SD
Test 2
Mean ± SD
ICC
(95% CI)
SRD % Mean
20°/s ccw 0.87 ± 0.15 0.80 ± 0.16 0.57
(0.36 - 0.76)
0.28 32.1
60°/s ccw 0.54 ± 0.21 0.50 ± 0.18 0.75
(0.59 - 0.86)
0.29 54.4
Reaction Times          
Auditory (ms) 256 ± 69 247 ± 76 0.76
(0.61 - 0.86)
99 38.4
Visual (ms) 266 ± 46 276 ± 56 0.33
(0.13 - 0.62)
121 43.5
Dual Task (ms) 457 ± 107 421 ± 118 0.78
(0.65 - 0.88)
158 32.6

SD = Standard Deviation, ICC = Intraclass Correlation Coefficient, CI = Confidence Interval, SRD = Smallest Real Difference, % Mean = SRD / Average Measure. CCW = Counterclockwise Optokinetic Stimulus, ms = milliseconds.