Skip to main content
. Author manuscript; available in PMC: 2019 Apr 3.
Published in final edited form as: NMR Biomed. 2018 Nov 20;32(1):e4029. doi: 10.1002/nbm.4029

FIGURE 6.

FIGURE 6

Comparing peak-to-peak cardiogenic oscillations in RBC spectral parameters during the breath-hold for healthy versus IPF subjects. Oscillations in the RBC amplitude, chemical shift, and phase are significantly larger for IPF subjects than healthy volunteers (P = 0.008, P = 0.001, and P = 0.002). The black bar with the asterisk indicates statistical difference between groups (P < 0.05)