Skip to main content
. 2019 Apr 1;15(2):85–89. doi: 10.5152/ejbh.2019.4619

Table 1.

Dosimetric parameters obtained for Planning Target Volume left chest wall by using IMRT and 3D-CRT techniques

Dosimetric Values IMRT 3D-CRT p
Maximum Dose (Gy) 5.579 5.529 0.51
Minimum Dose (Gy) 3.900 3.887 0.85
Mean Dose (Gy) 4.698 5.137 0.33
%95 Volume 4891 4717 0.04
Conformity index 1.31 1.73 0.03
Heterogeneity index 1.17 1.16 0.47
Monitor Unit 477 228 0.00

IMRT: intensity modulated radiotherapy techniques; 3D-CRT: three-dimensional conformal radiotherapy; Gy: gray