Handrup 2013
| Methods | Open‐label RCT; computer generated randomisation code in blocks of 20 | |
| Participants | n = 112 children aged 0‐19 years receiving a newly placed TCVC to facilitate chemotherapy (49% haematological, 51% solid tumours) 129 TCVCs inserted, including 113 TIDs and 16 TCVCs with external lines (TEs) |
|
| Interventions | Taurolidine/heparin/sodium citrate lock solution versus heparin lock solution | |
| Outcomes | *CRBSI *Exit‐site and tunnel infections *Mechanical complications |
|
| Notes | Followed up (catheters in situ) from 12 to 1176 days Type of CVC was a risk factor for CRBSI (TIDs were less likely to get infected than TEs) |
|
| Risk of bias | ||
| Bias | Authors' judgement | Support for judgement |
| Allocation concealment (selection bias) | Unclear risk | B ‐ Unclear |