Skip to main content
. Author manuscript; available in PMC: 2019 Sep 1.
Published in final edited form as: Clin Rev Bone Miner Metab. 2018 Sep 12;16(3):87–94. doi: 10.1007/s12018-018-9249-9

Table 3.

Correlations relating RPI and tissue-level/whole-bone mechanical behavior. N.S. denotes not significant.

Study Mechanical Parameter Relationship to IDI (R-value) Relationship to BMSi (R-value)
Granke et al., 2014 Femoral mid-shaft cortical beam 3-pt. bending ultimate stress −0.497 -
Femoral mid-shaft cortical beam 3-pt. bending toughness to failure −0.494 -
Granke et al., 2015 Femoral mid-shaft cortical beam crack initiation toughness −0.26
Abraham et al., 2015 Femoral neck failure load −0.478 -
Uppuganti et al., 2017 Tissue 3-pt. bending strength - +0.739
Tissue yield strength - +0.745
Tissue modulus - +0.722
Tissue toughness - n.s.