Skip to main content
. 2019 Jan 10;4(2):390–400. doi: 10.1016/j.adro.2018.12.003

Table 2.

Contouring variation data for all head and neck cancer data set structures

Structure Dice coefficient
Hausdorff distance (mm)
FDK_CBCT
Iterative_CBCT
P-value FDK_CBCT
Iterative_CBCT
P-value
Mean SD Mean SD Mean SD Mean SD
Brain stem 0.85 0.07 0.85 0.10 .48 7.01 2.34 7.51 2.95 .26
Parotid_L 0.83 0.09 0.86 0.07 .03 10.47 5.43 7.75 3.28 <.01
Parotid_R 0.85 0.07 0.86 0.06 .25 9.27 3.71 8.05 3.47 .05
Parotid_Combined 0.84 0.08 0.86 0.06 .03 9.87 4.65 7.90 3.35 <.01
SpinalCanal 0.92 0.02 0.92 0.02 .46 5.40 2.56 4.64 1.91 .09
Subman_L 0.83 0.10 0.80 0.12 .28 6.91 4.54 7.26 4.51 .31
Subman_R 0.79 0.21 0.77 0.17 .49 7.52 6.63 8.32 5.55 .16
Subman_Combined 0.81 0.16 0.79 0.15 .39 7.22 5.63 7.79 5.04 .14

Abbreviations: CBCT = cone beam computed tomography; FDK_CBCT = currently available algorithm; Iterative_CBCT = novel iterative algorithm; L = left; R = right; SD = standard deviation.

Data values correspond to statistically significant improvement.