Skip to main content
. 2019 Apr;63(4):270–276. doi: 10.4103/ija.IJA_852_18

Table 4.

Diagnostic accuracy and AUROC for airway tests predicting C&L grade III or IV assessed without BURP

Prediction Test Sensitivity (%) Specificity (%) PPV (%) NPV (%) Accuracy (%) Likelihood Ratio (+) AUROC
TMH test ≤50 mm 49.3 (37.4-61.3)a 70.5 (66.5-74.4)a 18.6 (13.3-24.8)a 91.1 (87.9-93.6)a 68.0 1.673 0.631 (0.56-0.70)a
TMH test ≤54 mm 65.8 (53.7-76.5)a 55.6 (51.3-59.9)a 16.8 (12.6-21.6)a 92.3 (88.8-94.9)a 56.8 1.481
TMD test ≤65 mm 6.8 (2.3-15.3)a 95.7 (93.6-97.3)a 17.9 (6.1-36.9)a 88.3 (85.4-90.8)a 85.1 1.596 0.636 (0.57-0.70)a
MMT class III, IV 37.0 (26.0-49.1)a 89.7 (86.9-92.2)a 32.9 (22.9-44.2)a 91.3 (88.5-93.5)a 83.4 3.604 0.708 (0.65-0.77)a

AUROC – Area under the receiver-operating characteristic curve; BURP – External, backward, upward, rightward pressure; C&L – Cormack Lehane; MMT – Modified Mallampati test; NPV – Negative predictive value; Likelihood ratio (+) – Positive likelihood ratio; PPV – Positive predictive value; TMD – Thyromental distance; TMH – Thyromental height a95% confidence intervals