Table 1.
The Names of the Power Plants, the Fuel(s) Utilized by the Facility, Observed HCl:SO2 Emission Ratios, the Standard Error Associated With the Emission Ratios, and the Correlation Coefficient Between HCl and SO2 (R2) for the Plume Encounters That Were Attributed to a Single Power Plant
| Plume number | Name of emission source (state) | Fuel utilized | Observed HCl:SO2 emission ratio ± standard error (R2) (ppt:ppb) |
|---|---|---|---|
| 2 | W H Zimmer (OH) | Coal/natural gas | 14.5 ± 2.6 (0.15) |
| 4 | P H Glatfelter (OH) | Coal/diesel | 7.3 ± 4.6 (0.03) |
| 11 | Chambersburg 12 and 13 (PA) | Natural gas | 53.0 ±1.4 (0.81) |
| 12 | Chambersburg 12 and 13 (PA) | Natural gas | 53.1 ± 2.0 (0.73) |
| 13 | Mountain (PA) | Natural gas/distillate fuel oil | 74.8 ± 1.2 (0.96) |
| 39 | Jack McDonough (GA) | Diesel/natural gas | 23.5 ± 13.2 (0.04) |
| 40 | Jack McDonough (GA) | Diesel/natural gas | 8.4 ± 22.4 (0.00) |
| 41 | Jack McDonough (GA) | Diesel/natural gas | 17.6 ± 15.6 (0.02) |
| 42 | Harllee Branch (GA) | Coal | 35.6 ± 1.4 (0.95) |
| 43 | Harllee Branch (GA) | Coal | 27.1 ± 2.7 (0.69) |
| 44 | Homer City (PA) | Coal | 28.8 ± 1.3 (0.94) |
| 45 | Mountour (PA) | Coal | 0.7 ± 1.1 (0.00) |
Note. OH = Ohio; PA = Pennsylvania; GA = Georgia.