Skip to main content
. 2017 Mar 15;2017(3):CD012600. doi: 10.1002/14651858.CD012600

Audibert 2001.

Clinical features and settings Routine screening
Participants 4130 participants
France ‐ single centre
May 1994 to December 1997
Pregnant women
Mean maternal age 30.1 years (all under 38 years), 86% < 35, 14% ≥ 35
Singleton pregnancies
10‐14 weeks' gestation
Crown‐rump length between 38 mm and 84 mm
Study design Prospective consecutive series study
Target condition and reference standard(s) Down's syndrome: 12 cases
Reference standards: prenatal karyotyping conducted (in 7.6% of patients) depending on presence of risk > 125, high maternal age, parental anxiety, history of chromosomal defects or parental translocation or abnormal second trimester scan age
Cytogenetic testing of newborns with suspected abnormalities
Postmortem on terminations of pregnancy or miscarriages
Follow‐up to neonatal examination in newborn
Index and comparator tests Maternal age
First trimester NT planned at 12‐13 weeks, 3 mm risk cut‐off
Second trimester serum hCG between 14 and 17 weeks (Amerlite, Orthoclinical diagnostics machine), cut‐off 1:250 (Prenata software)
Second trimester serum AFP between 14 and 17 weeks (Amerlite, Orthoclinical diagnostics machine), cut‐off 1:250 (Prenata software)
Serum tests in 3790 women
Follow‐up Delivery and postnatal paediatric examination
35 lost to follow‐up and excluded from analysis
Pregnancy loss in 37 women due to spontaneous abortion (n = 21) or intrauterine death (n = 16)
340 women had first trimester NT but not second trimester serum testing
Aim of study To compare first trimester NT and second trimester maternal serum measurements as alternative methods of antenatal screening in a low‐risk population and to evaluate the consequence of combining the results in the estimation of risk.
Notes Women lost to follow‐up are excluded in the final analysis. All antenatally detected cases were terminated.
Table of Methodological Quality
Item Authors' judgement Description
Representative spectrum? 
 All tests Yes Routine screening of typical pregnant population
Acceptable reference standard? 
 All tests Yes Karyotyping or follow‐up to birth
Partial verification avoided? 
 All tests Yes All women received a reference standard
Differential verification avoided? 
 All tests No Choice of reference standard depended on index test results
Incorporation avoided? 
 All tests Yes Reference standard was independent of the index test
Reference standard results blinded? 
 All tests No Reference standard interpreted with knowledge of index test results
Index test results blinded? 
 All tests Yes Index test interpreted without knowledge of reference standard results
Relevant clinical information? 
 All tests Yes Information available as would be in standard clinical practice 
Uninterpretable results reported? 
 All tests Yes NT was not measured or not recorded in 219 women and these patients were excluded from the study
Withdrawals explained? 
 All tests Yes 340 women who did not want second trimester serum screening withdrew from that part of the study