Skip to main content
. 2015 Feb 23;2015(2):CD004631. doi: 10.1002/14651858.CD004631.pub4
Methods Randomised controlled, patient‐blinded control trial
Exp: Uncemented hydroxyapatite‐ coated chrome‐cobalt Elektra screw cup
C: DLC all‐polyethylene cup
Participants Age (mean): Exp/C = 60/56
Gender (female/male): Exp/C = 12:1/12:2
Stage of OA (mean): Exp/C = not stated
Interventions Surgery Exp/C:
Exp: Uncemented hydroxyapatite‐coated chrome‐cobalt Elektra screw cup. Three weeks immobilisation post‐surgery. Return to full activities at 3 months.
C: DLC all‐polyethylene cup. Three weeks immobilisation post‐surgery. Return to full activities at 3 months.
Outcomes Pain: A 100 mm VAS was used to assess pain at rest and with activity.
Physical function: DASH score.
Patient global assessment: Not reported.
Range of motion: Not reported.
Trapeziometacarpal joint imaging: Stereoradiographs to measure implant migration over time.
Adverse events: Not reported.
Notes Follow‐up at "3 months, 6 months, 12 months, and 24 months after the operation".
Primary outcome of study was to measure implant migration.