Skip to main content
. 2018 Sep-Oct;44(5):370–377. doi: 10.1590/S1806-37562017000000118

Table3. Model for predicting the time to complete the Glittre ADL-test.

Variable Unstandardized coefficient (B) 95% CI for B p Part correlation Tolerance Variance inflation factor
Equation 1 Constant 3.049 2.095-4.004 < 0.01
Age, years 0.015 0.011-0.019 < 0.01 0.503 0.902 1.109
Height, cm −0.006 −0.011 to −0.001 0.02 −0.163 0.902 1.109
Equation 2 Constant 1.558 1.142-1.974 < 0.01
BMI 0.018 0.002-0.033 < 0.01 0.165 0.963 1.038
Age, years 0.016 0.012-0.019 < 0.01 0.530 0.963 1.038

ADL: activities of daily living; and BMI: body mass index. Equation 1: Glittre ADL-testpredicted = 3.049 + (0.015 × ageyears) + (−0.006 × heightcm); standard error of the estimate = 0.371. Equation 2: Glittre ADL-testpredicted = 1.558 + (0.018 × BMI) + (0.016 × ageyears); standard error of the estimate = 0.373.