Table 3.

Comparison of the anatomical sequences. ++ very good, + good, +− sufficient, − insufficient, RD—retinal detachment.

Evaluated Parameters Isotropic Sequences 2D Sequences Perpendicular to the Tumor—MS 2 mm
T2-Weighted T1-Weighted Before Contrast T1-Weighted After Contrast
MS TSE 3D TSE SPIR MS TSE MS TSE SPIR 3D TSE 3D TFE MS TSE SPIR 3D TSE SPIR 3D TFE PROSET MS T2 MS T1 MS T1 SPIR Gd
In-plane image quality
General image quality ++ + + + +− +− + +− + + + ++
Contrast + ++ +− + +− + ++ + ++ ++ + ++
Outer limit of sclera ++ + + + + + + ++ ++ +
Outer limits of tumor +− +− + + +− ++ + + + +
Differentiate tumor vs RD ++ ++ + ++
3D analysis
Geometrical accuracy
Good of complete eye 75% 78% 44% 44% 77% 100% 50% 88% 100%
Small local artefacts 25% 22% 33% 55% 11% 0% 25% 13% 0%
Not usable 0% 0% 22% 0% 11% 0% 25% 0% 0%
Outer limit of sclera ++ + +− +− + +− +