Working conditions of EDEN 350 machine.

PolyJet Process Parameters Value
Deposition layer thickness 0.016 mm
System vacuum level 6.2 atm
Temperature of each support head 72 °C
Block temperature behind support heads 72 °C
Block temperature in front of support heads 72 °C
Temperature of each model head 72 °C
Block temperature behind model heads 72 °C
Block temperature in front of model heads 72 °C
Pre-heating of support and model material 68 °C
Chamber temperature 20 °C
Relative humidity 30%