Skip to main content
. 2019 Mar 22;24(6):1143. doi: 10.3390/molecules24061143

Table 1.

Scan parameters of three types of ultrashort echo time (UTE) sequences and the Cones sequence with four different stretching factors (SFs) of 1.0, 1.2, 1.4, and 1.6.

3D UTE Sequences TEs #
(ms)
TR ##
(ms)
Resolution
(mm)
Matrix Scan Time
(mins)
Bandwidth
(kHz)
CSPI 0.528, 0.56, 0.592,
0.624, 0.656, 0.688
7 1 × 1 × 1 80 × 80 × 100 10′56″ ±250
PR 0.032, 0.132, 0.232,
0.332
7 1 × 1 × 1 140 × 140 × 100 5′38″ × 4 ±83.33
Cones
(SF = 1)
0.032, 0.132, 0.232,
0.332
7 1 × 1 × 1 140 × 140 × 100 2′36″ × 4 ±83.33
Cones
(SF = 1.2)
0.032, 0.132, 0.232,
0.332
7 1 × 1 × 1 140 × 140 × 100 2′03″ × 4 ±83.33
Cones
(SF = 1.4)
0.032, 0.132, 0.232,
0.332
7 1 × 1 × 1 140 × 140 × 100 1′48″ × 4 ±83.33
Cones
(SF = 1.6)
0.032, 0.132, 0.232,
0.332
7 1 × 1 × 1 140 × 140 × 100 1′32″ × 4 ±83.33

# TEs is Echo Times; ##> TR is Repetition Time.