Crowdsourced MRI quality metrics and expert quality annotations for training of humans and machines

Oscar Esteban 1,, Ross W Blair 1, Dylan M Nielson 2, Jan C Varada 3, Sean Marrett 3, Adam G Thomas 2, Russell A Poldrack 1, Krzysztof J Gorgolewski 1
PMCID: PMC6472378  PMID: 30975998

Abstract

The neuroimaging community is steering towards increasingly large sample sizes, which are highly heterogeneous because they can only be acquired by multi-site consortia. The visual assessment of every imaging scan is a necessary quality control step, yet arduous and time-consuming. A sizeable body of evidence shows that images of low quality are a source of variability that may be comparable to the effect size under study. We present the MRIQC Web-API, an open crowdsourced database that collects image quality metrics extracted from MR images and corresponding manual assessments by experts. The database is rapidly growing, and currently contains over 100,000 records of image quality metrics of functional and anatomical MRIs of the human brain, and over 200 expert ratings. The resource is designed for researchers to share image quality metrics and annotations that can readily be reused in training human experts and machine learning algorithms. The ultimate goal of the database is to allow the development of fully automated quality control tools that outperform expert ratings in identifying subpar images.

Subject terms: Computational neuroscience, Image processing, Databases, Magnetic resonance imaging


Design Type(s) data validation objective • source-based data transformation objective • anatomical image analysis objective
Measurement Type(s) Image Quality
Technology Type(s) digital curation
Factor Type(s)
Sample Characteristic(s) Homo sapiens • brain

Machine-accessible metadata file describing the reported data (ISA-Tab format)

Background & Summary

Ensuring the quality of neuroimaging data is a crucial initial step for any image analysis workflow because low-quality images may obscure the effects of scientific interest14. Most approaches use manual quality control (QC), which entails screening every single image of a dataset individually. However, manual QC suffers from at least two problems: unreliability and time-consuming nature for large datasets. Unreliability creates great difficulty in defining objective exclusion criteria in studies and stems from intrinsically large intra-rater and inter-rater variabilities5. Intra-rater variability derives from aspects such as training, subjectivity, varying annotation settings and protocols, fatigue or bookkeeping errors. The difficulty in calibrating between experts lies at the heart of inter-rater variability. In addition to the need for objective exclusion criteria, the current neuroimaging data deluge makes the manual QC of every magnetic resonance imaging (MRI) scan impractical. For these reasons, there has been great interest in automated QC58, which is progressively gaining attention916 with the convergence of machine learning solutions. Early approaches58 to objectively estimate image quality have employed “image quality metrics” (IQMs) that quantify variably interpretable aspects of image quality813 (e.g., summary statistics of image intensities, signal-to-noise ratio, coefficient of joint variation, Euler angle, etc.). The approach has been shown sufficiently reliable in single-site samples8,1113, but it does not generalize well to new images acquired at sites unseen by the decision algorithm9. Decision algorithms do not generalize to new datasets because the large between-site variability as compared to the within-site variability of features poses a challenging harmonization problem17,18, similar to “batch-effects” in genomic analyses19. Additional pitfalls limiting fully automated QC of MRI relate to the small size of databases that include quality annotations, and the unreliability of such annotations (or “labels noise”). As described previously, rating the quality of every image in large databases is an arduous, unreliable, and costly task. The convergence of limited size of samples annotated for quality and the labels noise preclude the definition of normative, standard values for the IQMs that work well for any dataset, and also, the generalization of machine learning solutions. Keshavan et al.15 have recently proposed a creative solution to the problem of visually assessing large datasets. They were able to annotate over 80,000 bidimensional slices extracted from 722 brain 3D images using BraindR, a smartphone application for crowdsourcing. They also proposed a novel approach to the QC problem by training a convolutional neural network on BraindR ratings, with excellent results (area under the curve, 0.99). Their QC tool performed as well as MRIQC9 (which uses IQMs and a random forests classifier to decide which images should be excluded) on their single-site dataset. By collecting several ratings per screened entity, they were able to effectively minimize the labels noise problem with the averaging of expert ratings. As limitations to their work, we would count the use of 2D images for annotation and the use of a single-site database. In sum, automating QC requires large datasets collected across sites, and rated by many individuals in order to ensure generalizability.

Therefore, the MRIQC Web-API (web-application program interface) provides a unique platform to address the issues raised above. The database collects two types of records: i) IQMs alongside corresponding metadata extracted by MRIQC (or any other compatible client) from T1w (T1-weighted), T2w (T2-weighted) and BOLD (blood-oxygen-level-dependent) MRI images; and ii) manual quality ratings from users of the MRIQC software. It is important to note that the original image data are not transferred to the MRIQC Web-API.

Within fourteen months we have collected over 50,000 and 60,000 records of anatomical and functional IQMs, respectively (Fig. 1). These IQMs are extracted and automatically submitted (unless the user opts out) with MRIQC (Fig. 2). Second, we leverage the efficiency of MRIQC’s reports in assessing individual 3D images with a simple interface that allows experts to submit their ratings with a few clicks (Fig. 3). This assessment protocol avoids clerical errors from the operator, as ratings are automatically handled and registered. In other words, MRIQC users are building a very large database with minimal effort every day. As only the IQMs and manual ratings are crowdsourced (i.e. images are not shared), data collection is not limited to public datasets only. Nonetheless, unique image checksums are stored in order to identify matching images. Therefore, such checksums allow users to find public images that IQMs and/or ratings derive from. The presented resource is envisioned to train automatic QC tools and to develop human expert training programs.

Fig. 1.

Fig. 1

A rapidly growing MRI quality control knowledge base. The database has accumulated over 50,000 records of IQMs generated for T1-weighted (T1w) images and 60,000 records for BOLD images. Records presented are unique, i.e. after exclusion of duplicated images.

Fig. 2.

Fig. 2

Experimental workflow to generate the database. A dataset is processed with MRIQC. Processing finishes with a POST request to the MRIQC Web API endpoint with a payload containing the image quality metrics (IQMs) and some anonymized metadata (e.g. imaging parameters, the unique identifier for the image data, etc.) in JSON format. Once stored, the endpoint can be queried to fetch the crowdsourced IQMs. Finally, a widget (Fig. 3) allows the user to annotate existing records in the MRIQC Web API.

Fig. 3.

Fig. 3

MRIQC visual reports and feedback tool. The visual reports generated with MRIQC include the “Rate Image” widget. After screening of the particular dataset, the expert can assign one quality level (among “exclude”, “poor”, “acceptable”, and “excellent”) and also select from a list of MR artifacts typically found in MRI datasets. When the annotation is finished, the user can download the ratings to their local hard disk and submit them to the Web API.

Methods

Here we describe an open database that collects both IQM vectors extracted from functional and anatomical MRI scans, along with quality assessments done by experts based on visual inspection of images. Although it was envisioned as a lightweight web-service tailored to MRIQC, the database is able to receive new records from any other software, provided they are able to correctly query the API (application programming interface).

Data generation and collection workflow

The overall framework involves the following workflow (summarized in Fig. 2):

  1. Execution of MRIQC and submission of IQMs: T1w, T2w, and BOLD images are processed with MRIQC, which computes a number of IQMs (described in section Technical Validation). The IQMs and corresponding metadata are formatted in JavaScript Object Notation (JSON), and MRIQC automatically submits them to a representational state transfer (REST) or RESTful endpoint of the Web-API. Users can opt-out if they do not wish to share their IQMs.

  2. JSON records are received by the endpoint, validated, and stored in the database. Each record includes the vector of IQMs, a unique checksum calculated on the original image, and additional anonymized metadata and provenance.

  3. Visualization of the individual reports: MRIQC generates dynamic HTML (hypertext markup language) reports that speed up the visual assessment of each image of the dataset. Since its version 0.12.2, MRIQC includes a widget (see Fig. 2) that allows the researcher to assign a quality rating to the image being screened.

  4. Crowdsourcing expert quality ratings: the RESTful endpoint receives the quality ratings, which are linked to the original image via their unique identifier.

  5. Retrieving records: the database can be queried for records with any HTTP (HyperText Transfer Protocol) client or via the web using our interface: https://mriqc.nimh.nih.gov/. Additionally, a snapshot of the database at the time of writing has been deposited to FigShare20.

Data Records

A full data snapshot of the database at the time of submission is available at FigShare20. Alternatively, data are accessible via DataLad21 with the dataset https://github.com/oesteban/mriqc-webapi-snapshot. Table 1 describes the structure of the dataset being released.

Table 1.

List of data tables retrieved from MRIQC-WebAPI.

Filename Size Description
bold.csv 71 MB IQMs and metadata of BOLD images (unique records)
bold_curated.csv 162 MB Same as bold.csv, after curation and checksum matching
T1w.csv 79 MB IQMs and metadata of T1w images (unique records)
T1w_curated.csv 110 MB Same as T1w.csv, after curation and checksum matching
T2w.csv 1.1 MB IQMs and metadata of T2w images (unique records)
T2w_curated.csv 1.7 MB Same as T2w.csv, after curation and checksum matching
rating.csv 131 kB Manually assigned quality annotations

The following datasets are available at FigShare20. The < name > _curated.csv file versions correspond to the original tables after matching checksums to images in publicly available databases (and further curation as shown in https://www.kaggle.com/chrisfilo/mriqc-data-cleaning).

To obtain the latest updated records, the database can be programmatically queried online to get all the currently stored records through its RESTful API.

MRIQC reports, generated for all T1w images found in OpenfMRI are available for expert training at https://mriqc.s3.amazonaws.com/index.html#openfmri/.

Technical Validation

MRIQC extends the list of IQMs from the quality assessment protocol10 (QAP), which was constructed from a careful review of the MRI and medical imaging literature. The technical validity of measurements stored to the database is demonstrated by our previous work9 on the MRIQC client tool and its documentation website: https://mriqc.readthedocs.io/en/latest/measures.html. Definitions for the anatomical IQMs are given in Table 2, and for functional IQMs in Table 3. Finally, the structure of data records containing the manual QC feedback is summarized in Table 4.

Table 2.

Summary table of image quality metrics for anatomical (T1w, T2w) MRI.

IQMs based on noise measurements
CJV The coefficient of joint variation of GM and WM was proposed as an objective function by Ganzetti et al.23 for the optimization of INU correction algorithms. Higher values are related to the presence of heavy head motion and large INU artifacts.
CNR The contrast-to-noise ratio24 is an extension of the SNR calculation to evaluate how separated the tissue distributions of GM and WM are. Higher values indicate better quality.
SNR MRIQC includes the signal-to-noise ratio calculation proposed by Dietrich et al.25, using the air background as noise reference. Additionally, for images that have undergone some noise reduction processing, or the more complex noise realizations of current parallel acquisitions, a simplified calculation using the within tissue variance is also provided.
QI2 The second quality index of Mortamet et al.8 is a calculation of the goodness-of-fit of a χ2 distribution on the air mask, once the artifactual intensities detected for computing the QI1 index have been removed. The description of the QI1 is found below.
IQMs based on information theory
EFC The entropy-focus criterion26 uses the Shannon entropy of voxel intensities as an indication of ghosting and blurring induced by head motion. Lower values are better.
FBER The foreground-background energy ratio10 is calculated as the mean energy of image values within the head relative to the mean energy of image values in the air mask. Consequently, higher values are better.
IQMs targeting specific artifacts
INU MRIQC measures the location and spread of the bias field extracted estimated by the intensity non-uniformity (INU) correction. The smaller spreads located around 1.0 are better.
QI1 Mortamet’s first quality index8 measures the number of artifactual intensities in the air surrounding the head above the nasio-cerebellar axis. The smaller QI1, the better.
WM2MAX The white-matter to maximum intensity ratio is the median intensity within the WM mask over the 95% percentile of the full intensity distribution, that captures the existence of long tails due to hyper-intensity of the carotid vessels and fat. Values should be around the interval [0.6, 0.8]
Other IQMs
FWHM The full-width half-maximum27 is an estimation of the blurriness of the image calculated with AFNI’s 3dFWHMx. Smaller is better.
ICVs Estimation of the intracranial volume (ICV) of each tissue calculated on the FSL fast’s segmentation. Normative values fall around 20%, 45% and 35% for cerebrospinal fluid (CSF), WM and GM, respectively.
rPVE The residual partial volume effect feature is a tissue-wise sum of partial volumes that fall in the range [5–95%] of the total volume of a pixel, computed on the partial volume maps generated by FSL fast. Smaller residual partial volume effects (rPVEs) are better.
SSTATs Several summary statistics (mean, standard deviation, percentiles 5% and 95%, and kurtosis) are computed within the following regions of interest: background, CSF, WM, and GM.
TPMs Overlap of tissue probability maps estimated from the image and the corresponding maps from the ICBM nonlinear-asymmetric 2009c template28.

MRIQC produces a vector of 64 image quality metrics (IQMs) per input T1w or T2w scan. (Reproduced from our previous work9).

Table 3.

Summary table of image quality metrics for functional (BOLD) MRI.

Spatial IQMs
EFC, FBER, FWHM, SNR, SSTATs (see Table 2)
IQMs measuring temporal variations
tSNR A simplified interpretation of the original temporal SNR definition by Krüger et al.29. We report the median value of the tSNR map calculated as the average BOLD signal across time over the corresponding temporal s.d. map.
GCOR Summary of time-series correlation as in30 using AFNI’s @compute_gcor
DVARS The spatial standard deviation of the data after temporal differencing. Indexes the rate of change of BOLD signal across the entire brain at each frame of data. DVARS is calculated using Nipype, after head-motion correction
IQMs targeting specific artifacts
FD Framewise Displacement - Proposed by Power et al.1 to regress out instantaneous head-motion in fMRI studies. MRIQC reports the average FD.
GSR The Ghost to Signal Ratio31 estimates the mean signal in the areas of the image that are prone to N/2 ghosts on the phase encoding direction with respect to the mean signal within the brain mask10. Lower values are better.
DUMMY The number of dummy scans - A number of volumes at the beginning of the fMRI time-series identified as nonsteady states.
IQMs from AFNI
AOR AFNI’s outlier ratio - Mean fraction of outliers per fMRI volume as given by AFNI’s 3dToutcount
AQI AFNI’s quality index - Mean quality index as computed by AFNI’s 3dTqual

MRIQC produces a vector of 64 image quality metrics (IQMs) per input BOLD scan.

Table 4.

Summary table of quality assessment values.

Expert rating
Exclude Assigned to images that show quality defects that preclude any type of processing
Poor Assigned to images that, although presenting some quality problem, may tolerate some types of processing. For instance, a T1w image that may be used as the co-registration reference, but will probably generate biased cortical thickness measurements.
Acceptable Assigned to images that do not show any substantial issue that may preclude processing
Excellent Assigned to images without quality issues
Artifacts
A vector of boolean values corresponding to the following list of possible artifacts found in the image:
• Head motion artifacts
• Eye spillover through phase-encoding axis
• Non-eye spillover through phase-encoding axis
• Coil failure
• Global noise
• Local noise
• Electromagnetic interference/perturbation
• Problematic field-of-view prescription/Wrap-around
• Aliasing ghosts
• Other ghosts
• Intensity non-uniformity
• Temporal field variation
• Reconstruction and postprocessing (e.g. denoising, defacing, resamplings)
• Uncategorized artifact

Annotations received through the feedback widget are stored in a separate database collecting one rating value and an array of artifacts present in the image.

Limitations

The main limitation of the database resides in that a substantial fraction of the records (e.g., around 50% for the BOLD IQMs) miss important information about imaging parameters. The original cause is that such information was not encoded with the input dataset being fed into MRIQC. However, as BIDS is permeating the current neuroimaging workflow we can expect BIDS datasets to become more complete, thereby allowing MRIQC to submit such valuable information to the Web API. Moreover, the gradual adoption of better DICOM-to-BIDS conversion tools such as HeuDiConv22, which automatically encodes all relevant fields in the BIDS structure, will surely help minimize this issue.

During the peer-review process of this manuscript, one reviewer identified a potential problem casting float numbers into integers on the content of the “bids_MagneticFieldStrength” field of all records. The bug was confirmed and consequently fixed on the MRIQC Web-API, and all records available on the database snapshot deposited at FigShare have been amended. When retrieving records directly from the Web-API, beware that those with creation date prior to Jan 16, 2019, require a revision of the tainted field. Similarly, the reviewer identified some 1,600 records with an echo-time (TE) value 30.0 with a repetition time (TR) of 2.0, which indicates that TE was misspecified in milliseconds (BIDS mandates seconds). Problematic data points can be (and are) present in the data, and there is likely no setup that could fully rule out the inclusion of misidentified results, although the automation in conversion above mentioned will surely minimize this problem.

Usage Notes

Primarily, the database was envisioned to address three use-cases:

  1. Sampling the distribution of IQMs and imaging parameters across datasets (including both publicly available and private), and across scanning sites.

  2. Ease the image QC process, crowdsourcing its outcomes.

  3. Training machines and humans.

These potential usages are revised with finer detail in the following. Note this resource is focused on quality control (QC), rather than quality assessment (QA). While QC focuses on flagging images that may endanger downstream analysis for their bad quality (i.e., identifying outliers), QA identifies issues that degrade all image’s quality (i.e., improving the overall quality of images after a problem spotted in the scanning device or acquisition protocol -via QC of actual images- is fixed).

Collecting IQMs and imaging parameters

Based on this information, researchers can explore questions such as the relationship of particular imaging parameters (e.g. MR scan vendor, or more interestingly, the multi-band acceleration factor of newest functional MRI sequences) with respect to the signal-to-noise ratio or the power of N/2 aliasing ghosts. Jupyter notebooks demonstrating examples of this use-case are available at https://www.kaggle.com/chrisfilo/mriqc/kernels.

Crowdsourcing an optimized assessment process

To our knowledge, the community lacks a large database of multi-site MRI annotated for quality that permits the application of machine learning techniques to automate QC. As Keshavan et al. have demonstrated, minimizing the time cost and fatigue load along with the elimination of bookkeeping tasks in the quality assessment of individual MR scans enables collection and annotation of massive datasets. The graphical user interface for this use-case is presented in Fig. 2.

A database to train machines and humans

Training machines

As introduced before, the major bottleneck in training models that can predict a quality score for an image or identify specific artifacts, without problems to generalize across MR scanners and sites, is the small size of existing datasets with corresponding quality annotations. Additionally, these annotations, if they exist, are done with extremely varying protocols. Thus, the ability of the presented database to crowdsource quality ratings assigned by humans after visual inspection addresses both problems. The availability of multi-site, large samples with crowdsourced quality annotations that followed a homogeneous protocol (the MRIQC reports) will allow building models that overperform the random forests classifier of MRIQC9, in the task of predicting the quality rating a human would have assigned to an image, given a vector of IQMs (i.e., from IQMs to quality labels). Matching public image checksums, this resource will also enable to train end-to-end (from images to quality labels) deep-learning solutions.

Training humans

Institutions can use the resource to train their experts and compare their assessments across themselves and against the existing quality annotations corresponding to publicly available datasets. Programs for training experts on quality assessment can be designed to leverage the knowledge shared via the proposed database.

ISA-Tab metadata file

Download metadata file (2.5KB, zip)

Acknowledgements

This work was supported by the Laura and John Arnold Foundation (R.A.P. and K.J.G.), the NIH (grant NBIB R01EB020740, Satrajit S. Ghosh), NIMH (R24MH114705 and R24MH117179, R.A.P.; ZICMH002884, Peter Bandettini; and ZICMH002960, A.G.T.), and NINDS (U01NS103780, R.A.P.).

Author Contributions

O.E. - Data curation, investigation, software, validation, visualization, writing & editing. R.W.B. - Conceptualization, investigation, software, validation, visualization, writing & editing. D.M.N. - Data curation, investigation, infrastructure, software, validation, writing & editing. J.C.V. - Investigation, infrastructure, software, validation, writing & editing. S.M. - Funding acquisition, infrastructure, resources, supervision, writing & editing. A.G.T. - Funding acquisition, infrastructure, resources, supervision, writing & editing. R.A.P. - Funding acquisition, resources, supervision, writing & editing. K.J.G. - Conceptualization, investigation, software, validation, resources, supervision, writing & editing.

Code Availability

The MRIQC Web API is available under the Apache-2.0 license. The source code is accessible through GitHub (https://github.com/poldracklab/mriqcwebapi).

MRIQC is one possible client to generate IQMs and submit rating feedback. It is available under the BSD 3-clause license. The source code is publicly accessible through GitHub (https://github.com/poldracklab/mriqc).

Competing Interests

The authors declare no competing interests.

Footnotes

Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

ISA-Tab metadata

is available for this paper at 10.1038/s41597-019-0035-4.

References

  • 1.Power JD, Barnes KA, Snyder AZ, Schlaggar BL, Petersen SE. Spurious but systematic correlations in functional connectivity MRI networks arise from subject motion. NeuroImage. 2012;59:2142–2154. doi: 10.1016/j.neuroimage.2011.10.018. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Yendiki A, Koldewyn K, Kakunoori S, Kanwisher N, Fischl B. Spurious group differences due to head motion in a diffusion MRI study. NeuroImage. 2014;88:79–90. doi: 10.1016/j.neuroimage.2013.11.027. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Reuter M, et al. Head motion during MRI acquisition reduces gray matter volume and thickness estimates. NeuroImage. 2015;107:107–115. doi: 10.1016/j.neuroimage.2014.12.006. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Alexander-Bloch A, et al. Subtle in-scanner motion biases automated measurement of brain anatomy from in vivo MRI. Hum. Brain Mapp. 2016;37:2385–2397. doi: 10.1002/hbm.23180. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Gardner EA, et al. Detection of degradation of magnetic resonance (MR) images: Comparison of an automated MR image-quality analysis system with trained human observers. Acad. Radiol. 1995;2:277–281. doi: 10.1016/S1076-6332(05)80184-9. [DOI] [PubMed] [Google Scholar]
  • 6.Woodard JP, Carley-Spencer MP. No-Reference image quality metrics for structural MRI. Neuroinformatics. 2006;4:243–262. doi: 10.1385/NI:4:3:243. [DOI] [PubMed] [Google Scholar]
  • 7.Gedamu EL, Collins DI, Arnold DL. Automated quality control of brain MR images. J. Magn. Reson. Imaging. 2008;28:308–319. doi: 10.1002/jmri.21434. [DOI] [PubMed] [Google Scholar]
  • 8.Mortamet B, et al. Automatic quality assessment in structural brain magnetic resonance imaging. Magn. Reson. Med. 2009;62:365–372. doi: 10.1002/mrm.21992. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Esteban O, et al. MRIQC: Advancing the automatic prediction of image quality in MRI from unseen sites. PLoS ONE. 2017;12:e0184661. doi: 10.1371/journal.pone.0184661. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Shehzad, Z. et al. The Preprocessed Connectomes Project Quality Assessment Protocol - a resource for measuring the quality of MRI data. In INCF Neuroinformatics, 10.3389/conf.fnins.2015.91.00047 (2015).
  • 11.Pizarro, R. A. et al. Automated Quality Assessment of Structural Magnetic Resonance Brain Images Based on a Supervised Machine Learning Algorithm. Front. Neuroinformatics. 10, 10.3389/fninf.2016.00052 (2016). [DOI] [PMC free article] [PubMed]
  • 12.Backhausen, L. L. et al. Quality Control of Structural MRI Images Applied Using FreeSurfer—A Hands-On Workflow to Rate Motion Artifacts. Front. Neurosci. 10, 10.3389/fnins.2016.00558 (2016). [DOI] [PMC free article] [PubMed]
  • 13.Alfaro-Almagro, F. et al. Image processing and Quality Control for the first 10,000 brain imaging datasets from UK Biobank. NeuroImage, 10.1016/j.neuroimage.2017.10.034 (2017). [DOI] [PMC free article] [PubMed]
  • 14.White T, et al. Automated quality assessment of structural magnetic resonance images in children: Comparison with visual inspection and surface-based reconstruction. Hum. Brain Mapp. 2018;39:1218–1231. doi: 10.1002/hbm.23911. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Keshavan, A., Yeatman, J. & Rokem, A. Combining citizen science and deep learning to amplify expertise in neuroimaging. Preprint at, 10.1101/363382 (2018). [DOI] [PMC free article] [PubMed]
  • 16.Klapwijk ET, van de Kamp F, van der Meulen M, Peters S, Wierenga LM. Qoala-T: A supervised-learning tool for quality control of FreeSurfer segmented MRI data. NeuroImage. 2019;189:116–129. doi: 10.1016/j.neuroimage.2019.01.014. [DOI] [PubMed] [Google Scholar]
  • 17.Fortin J-P, et al. Harmonization of cortical thickness measurements across scanners and sites. NeuroImage. 2018;167:104–120. doi: 10.1016/j.neuroimage.2017.11.024. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Nielson DM, et al. Detecting and harmonizing scanner differences in the ABCD study - annual release 1.0. Preprint at. 2018 doi: 10.1101/309260. [DOI] [Google Scholar]
  • 19.Leek JT, et al. Tackling the widespread and critical impact of batch effects in high-throughput data. Nat. Rev. Genet. 2010;11:733–739. doi: 10.1038/nrg2825. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Esteban, O. et al. MRIQC WebAPI - Database snapshot. figshare, 10.6084/m9.figshare.7097879.v4 (2019).
  • 21.Halchenko Y, et al. Open Source Software: DataLad. Zenodo. 2017 doi: 10.5281/zenodo.1000098. [DOI] [Google Scholar]
  • 22.Halchenko, Y. O. et al. Open Source Software: Heudiconv. Zenodo, 10.5281/zenodo.1306159 (2018).
  • 23.Ganzetti, M., Wenderoth, N. & Mantini, D. Intensity Inhomogeneity Correction of Structural MR Images: A Data-Driven Approach to Define Input Algorithm Parameters. Front. Neuroinformatics. 10, 10.3389/fninf.2016.00010 (2016). [DOI] [PMC free article] [PubMed]
  • 24.Magnotta VA, Friedman L, Birn F. Measurement of Signal-to-Noise and Contrast-to-Noise in the fBIRN Multicenter Imaging Study. J. Digit. Imaging. 2006;19:140–147. doi: 10.1007/s10278-006-0264-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO. Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters. J. Magn. Reson. Imaging. 2007;26:375–385. doi: 10.1002/jmri.20969. [DOI] [PubMed] [Google Scholar]
  • 26.Atkinson D, Hill DLG, Stoyle PNR, Summers PE, Keevil SF. Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion. IEEE Trans. Med. Imaging. 1997;16:903–910. doi: 10.1109/42.650886. [DOI] [PubMed] [Google Scholar]
  • 27.Friedman L, et al. Test–retest and between-site reliability in a multicenter fMRI study. Hum. Brain Mapp. 2008;29:958–972. doi: 10.1002/hbm.20440. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.Fonov V, et al. Unbiased average age-appropriate atlases for pediatric studies. NeuroImage. 2011;54:313–327. doi: 10.1016/j.neuroimage.2010.07.033. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Krüger G, Glover GH. Physiological noise in oxygenation-sensitive magnetic resonance imaging. Magn. Reson. Med. 2001;46:631–637. doi: 10.1002/mrm.1240. [DOI] [PubMed] [Google Scholar]
  • 30.Saad ZS, et al. Correcting Brain-Wide Correlation Differences in Resting-State FMRI. Brain Connect. 2013;3:339–352. doi: 10.1089/brain.2013.0156. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Giannelli, M., Diciotti, S., Tessa, C. & Mascalchi, M. Characterization of Nyquist ghost in EPI-fMRI acquisition sequences implemented on two clinical 1.5 T MR scanner systems: effect of readout bandwidth and echo spacing. J. Appl. Clin. Med. Phys. 11 (2010). [DOI] [PMC free article] [PubMed]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Download metadata file (2.5KB, zip)

Data Availability Statement

The MRIQC Web API is available under the Apache-2.0 license. The source code is accessible through GitHub (https://github.com/poldracklab/mriqcwebapi).

MRIQC is one possible client to generate IQMs and submit rating feedback. It is available under the BSD 3-clause license. The source code is publicly accessible through GitHub (https://github.com/poldracklab/mriqc).


Articles from Scientific Data are provided here courtesy of Nature Publishing Group

RESOURCES