. 2014 Nov 13;2014(11):CD009519. doi: 10.1002/14651858.CD009519.pub2

Li 2012a.

Study characteristics
Patient sampling Retrospective? consecutive?patient series
Patient characteristics and setting 80 patients, mean age = 58 (range = 35‐84) years, 52 males/28 females, China
Histology of primary tumour: Not reported. Comorbidities: Not reported.
Inclusion criteria:
 Patients with NSCLC who underwent curative surgical resection with regional lymph node dissection after 18F‐FDG PET/CT and breath‐hold spiral CT between October 2006 and March 2009.
Exclusion criteria:
 None listed.
Previous/all tests :
 Not reported.
Clinical setting:
 Secondary/tertiary setting
The inclusion criteria narrows the range of patients who would receive PET‐CT in practice, namely, patients (clinically) with suspected resectable non‐small cell lung cancer, a proportion of whom would have N2 or N3 disease on PET‐CT
Index tests FDG PET‐CT were acquired on an integrated PET‐CT device (GE Discovery ST16) that consisted of a PET scanner and a 16‐slice CT scanner. The participants fasted for ≥ 6 hours, and after a normal blood glucose level was ensured (≤ 8 mmol/L), received an intravenous injection of FDG 3.7 to 4.44 MBq/kg and then rested for 50 to 70 min before undergoing the scan. 2 chest radiologists with PET‐CT diagnostic experience evaluated the PET‐CT datasets. Nodal status was determined by SUV associated with CT attenuation. Additionally, if FDG uptake was positive, lymph nodes with calcification or higher attenuation than the aorta on the CT images were considered benign
Covariates
Type of PET‐CT scanner: integrated PET‐CT device (GE Discovery ST16)
FDG dose: 3.7 to 4.44 MBq/kg
Injection‐to‐scan time: 50 to 70 min
Attenuation correction: yes
Cut‐off values for test positivity (malignancy): Nodal positive FDG uptake was defined visually as a level greater than that of the surrounding mediastinum background
Target condition and reference standard(s) Pathology from lung resection with mediastinal lymph node dissection
Flow and timing All participants were accounted for in the results. All participants received the reference standard. There were no uninterpretable results
Comparative  
Notes The study was supported by the National Science and Technology Major Projects (2009ZX09501‐026), Doctoral Fund of Ministry of Education of China (20070023041) and Beijing Hope Run Special Fund (grant LC2007A02).
Adverse events: None reported
Methodological quality
Item Authors' judgement Risk of bias Applicability concerns
DOMAIN 1: Patient Selection
Was a consecutive or random sample of patients enrolled? Unclear    
Was a case‐control design avoided? Yes    
Did the study avoid inappropriate exclusions? Unclear    
    Unclear High
DOMAIN 2: Index Test All tests
Were the index test results interpreted without knowledge of the results of the reference standard? Yes    
Was there a pre‐specified cut‐off value? No    
Was a positive result defined? Yes    
    Low Low
DOMAIN 3: Reference Standard
Is the reference standards likely to correctly classify the target condition? Yes    
Were the reference standard results interpreted without knowledge of the results of the index tests? Unclear    
    Low Low
DOMAIN 4: Flow and Timing
Was there an appropriate interval between index test and reference standard? Yes    
Did all patients receive the same reference standard? Yes    
Were all patients included in the analysis? Yes    
    Low