Skip to main content
. 2019 Apr 16;10:322. doi: 10.3389/fneur.2019.00322

Table 4.

Embolic signal counts and effective monitoring time for study arteries according to 4-hourly intervals from midnight.

Patient/study artery No. Midnight-0400 0400–0800 0800-Midday Midday-1600 1600–2000 2000–2400 Total ES Total time
ES Time ES Time ES Time ES Time ES Time ES Time
1 0 240 1 207 3 165 0 52 0 75 0 165 4 904
(15.1 h)
2 0 220 0 103 1 189 0 186 0 148 0 159 1 1005
(16.8 h)
3 0 235 0 233 0 125 2 207 1 215 0 208 3 1223
(20.4 h)
4 0 240 0 225 0 226 0 195 0 202 0 190 0 1278
(21.3 h)
5 0 240 0 191 0 115 0 185 0 219 0 156 0 1106
(18.4 h)
6 3 276 5 200 2 112 3 198 3 185 4 240 20 1211
(20.2 h)
7 1 204 7 165 10 158 9 191 1 139 0 205 28 1062
(17.7 h)
8 0 182 0 0 0 156 0 137 0 228 0 221 0 924
(15.4 h)
9 0 0 0 223 0 79 0 130 0 190 0 95 0 717
(12.0 h)
10 0 225 0 218 0 171 0 190 0 214 0 225 0 1243
(20.7 h)
Totals/
time of day
ES detected 4 13 16 14 5 4 56
Effective monitoring time 2062 min = 34.37 h 1765 min = 29.42 h 1496 min = 24.93 h 1671 min = 27.85 h 1815 min = 30.25 h 1864 min = 31.07 h 10673 min = 177.88 h
Average ES/effective monitoring hour by time of day 0.12 (TROUGH) 0.44 0.64 (PEAK) 0.50 0.17 0.13 0.31

Time is in minutes unless otherwise specified. ES, embolic signal.