Study characteristics |
Patient sampling |
Prospective cross‐sectional study |
Patient characteristics and setting |
91 adult patients. Child A: 19%. Setting: tertiary referral centre in Mexico |
Index tests |
Platelet count‐to‐spleen diameter ratio |
Target condition and reference standard(s) |
Presence of any oesophageal varices. Upper endoscopy |
Flow and timing |
|
Comparative |
|
Notes |
|
Methodological quality |
Item |
Authors' judgement |
Risk of bias |
Applicability concerns |
DOMAIN 1: Patient Selection |
Was a consecutive or random sample of patients enrolled? |
Unclear |
|
|
Was a case‐control design avoided? |
Yes |
|
|
Did the study avoid inappropriate exclusions? |
Yes |
|
|
|
|
Unclear |
Low |
DOMAIN 2: Index Test Platelet count to spleen length ratio |
Were the index test results interpreted without knowledge of the results of the reference standard? |
Yes |
|
|
If a threshold was used, was it pre‐specified? |
No |
|
|
|
|
High |
Low |
DOMAIN 3: Reference Standard |
Is the reference standards likely to correctly classify the target condition? |
Yes |
|
|
Were the reference standard results interpreted without knowledge of the results of the index tests? |
Yes |
|
|
|
|
Low |
Low |
DOMAIN 4: Flow and Timing |
Was there an appropriate interval between index test and reference standard? |
Unclear |
|
|
Did all patients receive the same reference standard? |
Yes |
|
|
Were all patients included in the analysis? |
Yes |
|
|
|
|
Unclear |
|