Skip to main content
. 2017 Apr 26;2017(4):CD008759. doi: 10.1002/14651858.CD008759.pub2

Wang CC 2015.

Study characteristics
Patient sampling Cross‐sectional study
Patient characteristics and setting 42 adult patients. Child A: not reported. Setting: tertiary referral centre in Taiwan
Index tests Spleen diameter
Target condition and reference standard(s) Presence of any oesophageal varices. Upper endoscopy
Flow and timing  
Comparative  
Notes Abstract
Methodological quality
Item Authors' judgement Risk of bias Applicability concerns
DOMAIN 1: Patient Selection
Was a consecutive or random sample of patients enrolled? No    
Was a case‐control design avoided? Yes    
Did the study avoid inappropriate exclusions? Unclear    
    High Low
DOMAIN 2: Index Test Spleen length
Were the index test results interpreted without knowledge of the results of the reference standard? Unclear    
If a threshold was used, was it pre‐specified? No    
    High Low
DOMAIN 3: Reference Standard
Is the reference standards likely to correctly classify the target condition? Yes    
Were the reference standard results interpreted without knowledge of the results of the index tests? Unclear    
    Unclear Low
DOMAIN 4: Flow and Timing
Was there an appropriate interval between index test and reference standard? Unclear    
Did all patients receive the same reference standard? Yes    
Were all patients included in the analysis? Yes    
    Unclear