Skip to main content
. Author manuscript; available in PMC: 2019 Apr 24.
Published in final edited form as: Ultrasound Med Biol. 2018 Jan 2;44(3):522–531. doi: 10.1016/j.ultrasmedbio.2017.11.018

Table 4.

Summary of jet number, total surface area and total PD area between normal and pre-eclamptic (PET) subjects.

   NON-PET   PET

Measure Distance n Mean ± Std. Dev n Mean ± Std.
Dev
p
Number of Jets 2mm 134 17.23 ± 9.41 9 6.56 ± 5.70 0.005
Total Area (cm2) 52.23 ± 16.96 34.11 ± 11.99 0.008
Total PD Area (cm2) 7.69 ± 5.56 2.15 ± 2.76 0.005
Number Oo Jets 3mm 133 13.26 ± 7.61 9 4.22 ± 4.84 0.005
Total Area (cm2) 47.19 ± 16.19 29.91 ± 11.62 0.008
Total PD Area (cm2) 5.86 ± 4.89 1.84 ± 2.14 0.01
Number of Jets 4mm 133 9.47 ± 6.38 7 3.71 ± 4.19 0.028
Total Area (cm2) 41.06 ± 14.50 28.52 ± 8.17 0.032
Total PD Area (cm2) 3.54 ± 3.30 1.42 ± 1.83 0.045