Percentage error (%) between experimental and analytical data for pressure taps with sub-channel width w3=162μm.

Re Re
101 100 10 102 101 100 10 102 Section
α1 69.3 86.0 74.7 R1 71.5 57.8 53.9 AB
73.3 71.5 79.8 23.9 32.6 35.6 BC
50.5 78.1 74.6 15.2 35.6 42.1 CD
59.8 81.9 77.4 24.6 15.8 32.9 AD
α2 64.4 79.6 67.0 R2 58.2 64.3 AB
53.9 25.2 56.8 38.9 16.1 30.2 BC
72.4 71.4 64.1 26.6 45.1 43.2 CD
70.4 63.9 68.8 55.1 41.4 36.6 AD
α3 63.7 79.7 65.6 R3 56.2 64.6 57.0 AB
26.7 64.8 59.6 35.6 15.9 40.8 BC
64.2 55.0 56.2 41.1 35.0 52.9 CD
18.8 66.6 56.7 28.7 35.9 42.8 AD