Mossafa 2005.
Methods | RCT Setting: Iran Funding: unspecified |
|
Participants | 40 participants with femoral neck fracture | |
Interventions |
Treatment group: fascia iliaca block with 20 mL 1.5% lidocaine (n = 20) Control group: IV fentanyl 1.5 mcg/kg (n = 20) Lateral decubitus position for spinal anaesthesia |
|
Outcomes | Pain on movement 5 minutes after block placement (positioning for spinal) Participant satisfaction |
|
Notes | Conference abstract Email sent on 26 May 2015; no reply |
|
Risk of bias | ||
Bias | Authors' judgement | Support for judgement |
Random sequence generation (selection bias) | Unclear risk | "Randomized", no details |
Allocation concealment (selection bias) | Unclear risk | Not mentioned |
Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Not mentioned |
Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Not mentioned |
Incomplete outcome data (attrition bias) All outcomes | Low risk | None lost to follow‐up |
Selective reporting (reporting bias) | Low risk | All measurements mentioned in methods section given in results section |
Other bias | Unclear risk | No details |