Table 5.

Diagnostic values of perfusion factors for predicting anastomotic complications (n = 86)

Slope T 1/2MAX TR
Sensitivity 66.7% (4/6) 100% (6/6) 83.3% (5/6)
Specificity 92.5% (74/80) 83.7% (67/80) 96.3% (77/80)
PPV 40% (4/10) 31.6% (6/19) 62.5% (5/8)
NPV 97.4% (74/76) 100% (67/67) 98.7% (77/78)
Accuracy 90.7% (78/86) 84.9% (73/86) 95.3% (82/86)

PPV positive predictive value, NPV negative predictive value, Cut-off values (2 categories), Slope (slow < 0.7 AU/sec), T1/2MAX (slow > 18 s), TR time ratio (slow > 0.6)