Skip to main content
. 2019 Feb 22;47(8):e46. doi: 10.1093/nar/gkz107

Table 1.

Accuracy and support of haplotyping methods on pure-strain reads

Method AUROC Accuracy (%) Called reads
Basecall 0.976 0.963 261 806
Signal 0.988 0.961 199 474
Regression 0.992 0.972 198 684
Ad hoc 0.983 228 866