Table 2.
Comparison of marginal gap between the crowns fabricated by conventional and computer-aided design and computer-assisted manufacturing techniques (μm)
| Surfaces | Method | Mean | Mean rank | Sum of ranks | Mann-Whitney U | P |
|---|---|---|---|---|---|---|
| Buccal | CAD-CAM | 42.68 | 11.43 | 171.50 | 51.500 | 0.011* |
| Conventional | 52.46 | 19.57 | 293.50 | |||
| Mesiobuccal | CAD-CAM | 15.94 | 11.03 | 165.50 | 45.500 | 0.005** |
| Conventional | 30.13 | 19.97 | 299.50 | |||
| Mesial | CAD-CAM | 21.26 | 13.87 | 208.00 | 88.000 | 0.306 |
| Conventional | 29.22 | 17.13 | 257.00 | |||
| Mesiolingual | CAD-CAM | 29.59 | 13.30 | 199.50 | 79.500 | 0.171 |
| Conventional | 41.88 | 17.70 | 265.50 | |||
| Lingual | CAD-CAM | 42.04 | 14.43 | 216.50 | 96.500 | 0.507 |
| Conventional | 42.92 | 16.57 | 248.50 | |||
| Distolingual | CAD-CAM | 26.70 | 12.23 | 183.50 | 63.500 | 0.042* |
| Conventional | 43.86 | 18.77 | 281.50 | |||
| Distal | CAD-CAM | 12.38 | 11.17 | 167.50 | 47.500 | 0.006** |
| Conventional | 31.45 | 19.83 | 297.50 | |||
| Distobuccal | CAD-CAM | 24.11 | 12.83 | 192.50 | 72.500 | 0.097 |
| Conventional | 38.76 | 18.17 | 272.50 |
*P<0.05, **P<0.01. CAD-CAM=Computer-aided design and computer-assisted manufacturing