2. Adverse effects: intraoperative complications.
Study |
Study population: number of participants (number of eyes) |
Number of intraoperative complication(s) | Details of intraoperative complication(s) |
Bandyopadhyay 2016 | Blue‐light filtering IOLs: n = 65 (65); this group combined individuals assigned to 2 different blue‐light filtering IOLs Non‐blue‐light filtering IOL: n = 33 (33) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Barisic 2007 | Blue‐light filtering IOL: n = 30 (60) Non‐blue‐light filtering IOL: n = 30 (60) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Caporossi 2007 | Blue‐light filtering IOL: n = 50 (100); this group combined individuals assigned to 2 different blue‐light filtering IOLs Non‐blue‐light filtering IOL: n = 75 (150); this group combined individuals assigned to 3 different non‐blue‐light filtering IOLs |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Cui 2009 | Blue‐light filtering IOL: n = 39 (41) Non‐blue‐light filtering IOL: n = 18 (20) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Cuthbertson 2009 | Overall: n = 31 (31) | Not reported | One participant developed endophthalmitis and was removed from the trial, being replaced (after re‐randomisation) by another individual. There was one anterior capsular rim tear and one posterior capsule tear without vitreous loss. No details were provided in relation to which group(s) the adverse events occurred in. |
Espíndola 2012a | Blue‐light filtering IOL: n = 27 (27) Non‐blue‐light filtering IOL: n = 52 (77) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Falkner Radler 2008 | Blue‐light filtering IOL: n = 30 (30) Non‐blue‐light filtering IOL: n = 30 (30) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Kim 2011a | Blue‐light filtering IOL: n = ? (42) Non‐blue‐light filtering IOL: n = ? (26) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Kim 2011b | Blue‐light filtering IOL: n = 23 (23) Non‐blue‐light filtering IOL: n = 16 (16) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Leibovitch 2006 | Blue‐light filtering IOL: n = 9 (9) Non‐blue‐light filtering IOL: n = 10 (10) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Marshall 2005 | Blue‐light filtering IOL: n = 150 (300) Non‐blue‐light filtering IOL: n = 147 (294) |
Blue‐light filtering IOL: n = 1 Non‐blue‐light filtering IOL: none |
There was one case of lens dislocation during surgery in the blue‐light filtering IOL group, in a case in which a posterior capsule rupture had occurred during cataract extraction. |
Monnet 2009 | Blue‐light filtering IOL: n = 19 (19) Non‐blue‐light filtering IOL: n = 40 (40); this group combined individuals assigned to 2 different non‐blue‐light filtering IOLs. |
Blue‐light filtering IOL: n = 2 Non‐blue‐light filtering IOL: none |
In the blue‐light filtering IOL lens group "two IOLs were placed with 1 haptic in the capsular bag and 1 haptic outside the capsular bag; these 2 patients were also excluded from the final statistical analysis." |
Pandita 2007 | Blue‐light filtering IOL: n = 73 (73); this group combined individuals assigned to 2 different blue‐light filtering IOLs. Non‐blue‐light filtering IOL: n = 36 (36) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Raj 2005 | Blue‐light filtering IOL: n = 30 (30) Non‐blue‐light filtering IOL: n = 30 (30) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Schmidinger 2008 | Blue‐light filtering IOL: n = 31 (31) Non‐blue‐light filtering IOL: n = 31 (31) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
Vuori 2006 | Blue‐light filtering IOL: n = 19 (25) Non‐blue‐light filtering IOL: n = 18 (27) |
Blue‐light filtering IOL: none Non‐blue‐light filtering IOL: none |
Not applicable |
IOL: intraocular lens