Skip to main content
. 2018 May 22;2018(5):CD011977. doi: 10.1002/14651858.CD011977.pub2

Hyunseok 2007.

Methods Study design: RCT
Study grouping: parallel group, involving 48 eyes from 42 individuals
Exclusions after randomisation: not reported
Losses to follow‐up: not reported
How missing data were handled: not reported
Reported power size calculation? no
Participants Baseline characteristics
Blue‐light filtering IOL group
  • Number of participants: number of people (number of eyes): ? (26)

  • Sex (number of women/number of men): not reported

  • Age (mean ± unit of error): not reported


Non‐blue‐light filtering IOL group
  • Number of participants: number of people (number of eyes): ? (22)

  • Sex (number of women/number of men): not reported

  • Age (mean ± unit of error): not reported


Inclusion criteria: not reported
Exclusion criteria: not reported
Comparison of study groups at baseline: not reported
Interventions Intervention characteristics
Blue‐light filtering IOL
  • Type of IOL: AcrySof SN60AT (Alcon)


Non‐blue‐light filtering IOL
  • Type of IOL: Tecnis ZA9003 (AMO)

Outcomes Wavefront analysis by iTrace (Tracey technologies), and contrast sensitivity test at three months post‐surgery
Identification Sponsorship source:
Funding sources: not reported
Declaration of interest: not reported
Country: not reported
Setting: not reported
Comments:
Date study conducted: not reported
Trial registration number: not reported
Contacting study investigators: study authors contacted for more information about abstract; no additional information provided for review.
First author's name: Ahn Hyunseok MD
Institution: not reported
Email: not reported
Address: not reported
Notes AAO conference abstract
Risk of bias
Bias Authors' judgement Support for judgement
Random sequence generation (selection bias) Unclear risk Judgement comment: not reported how list was generated
Allocation concealment (selection bias) Unclear risk Judgement comment: not reported how allocation administered. Study is described as “randomised” but with no further details
Blinding of participants and personnel (performance bias) 
 All outcomes High risk Judgement comment: no information provided on masking
Blinding of outcome assessment (detection bias) 
 All outcomes High risk Judgement comment: no information provided on masking
Incomplete outcome data (attrition bias) 
 All outcomes Unclear risk Judgement comment: follow‐up not reported
Selective reporting (reporting bias) Unclear risk Judgement comment: no access to protocol or trials registry entry
Other bias Unclear risk Judgement comment: insufficient detail in abstract to judge whether other sources of bias are present