Skip to main content
. 2019 Apr 24;75(1):469. doi: 10.4102/sajp.v75i1.469

TABLE 3b.

Intra-rater reliability of the screening tests in this study.

Rater Test Session 1 outcomes (n = 31)
Session 2 outcomes (n = 31)
k (95% CI) SEM
Motion detected by rater
Motion detected by rater
Up Down None Up Down None
SST
1 Left 16.00 (51.60) 4.00 (12.90) 11.00 (35.50) 14.00 (45.20) 13.00 (41.90) 3.00 (9.70) −0.06 (−0.27–0.10) 0.10
Right 17.00 (54.80) 6.00 (19.40) 8.00 (25.80) 11.00 (35.50) 18.00 (58.10) 2.00 (6.50) −0.15 (−0.40–0.40) 0.10
2 Left 0.00 (0.00) 16.00 (51.60) 15.00 (48.40) 0.00 (0.00) 22.00 (70.90) 9.00 (29.00) 0.10 (−0.20-0.40) 0.20
Right 0.00 (0.00) 24.00 (77.40) 7.00 (22.60) 0.00 (0.00) 27.00 (87.10) 4.00 (12.90) −0.20 (−0.30–0.10) 0.10

k, kappa; SEM, standard error measurement; CI, confidence interval.