. 2019 Apr 26;10:385. doi: 10.3389/fneur.2019.00385

Figure 3.

Figure 3

Movement lateralization: timing performance of the right hand (RH) on the single-hand task (UNI) and on the bimanual task (BI). Data of both patients with Tourette syndrome (TS) and healthy control subjects (HC) are shown. The results of the synchronization (SYNC) and continuation (CONT) tasks with a supra-second (0.5 Hz, 2,000 ms ISI) and sub-second (2 Hz, 500 ms ISI) time interval are shown. On the x-axis, we show the type of task. On the y-axis, we show the duration of the temporal error in ms (A,B) and the IRA expressed as a ratio between the time interval reproduced by the subject and the time interval set by the metronome (C,D). Asterisks indicate when statistical analysis showed a significant difference (*p < 0.05). Mean data + standard error mean (SEM) are shown.