Skip to main content
. 2019 Jan 6;7(2):316–325. doi: 10.1177/2050640618822402

Table 2.

Polyp diagnosis using HDWL and BLI in experienced and trainee groups.

Variable HDWL % (95% CI) BLI % (95% CI) Odds ratioa (95% CI) p value
Experienced group
 Sensitivity 69 (60, 77) 79 (69, 85) 2.52 (1.14, 5.59) 0.02
 Specificity 97 (92, 99) 95 (90, 99) 0.43 (0.10, 1.99) 0.28
 PPV 96 (93, 100) 94 (90, 98) 0.58 (0.14, 2.38) 0.45
 NPV 75 (69, 83) 81 (73, 88) 1.46 (0.81, 2.61) 0.21
 Accuracy 83 (78, 87) 87 (82, 91) 1.70 (0.86, 3.38) 0.13
 High confidence 52 (45, 58) 71 (65, 77) 2.80 (1.77, 4.43) <0.001
Trainee group
 Sensitivity 75 (67, 82) 79 (70, 85) 1.43 (0.68, 3.02) 0.35
 Specificity 97 (93, 98) 96 (93, 99) 0.72 (0.15, 3.56) 0.69
 PPV 97 (91, 99) 96 (89, 98) 0.79 (0.17, 3.65) 0.77
 NPV 79 (72, 87) 82 (74, 88) 1.20 (0.65, 2.19) 0.56
 Accuracy 86 (81, 91) 88 (83, 92) 1.26 (0.65, 2.48) 0.49
 High confidence 40 (35, 48) 67 (60, 72) 2.95 (2.01, 4.33) <0.001
All
 Sensitivity 72 (64, 77) 79 (72, 84) 1.87 (1.09, 3.20) 0.02
 Specificity 97 (94, 99) 95 (92, 98) 0.55 (0.19, 1.64) 0.29
 PPV 96 (92, 98) 95 (91, 97) 0.66 (0.24, 1.86) 0.43
 NPV 77 (71, 81) 81 (77, 86) 1.33 (0.87, 2.02) 0.18
 Accuracy 84 (81, 88) 87 (84, 90) 1.46 (0.91, 2.35) 0.12
 High confidence 46 (42, 50) 69 (64, 73) 2.70 (2.03, 3.58) <0.001

BLI: Blue Light Imaging; CI: confidence interval; HDWL: high-definition white light; NPV: negative predictive value; PPV: positive predictive value.