FIG. 2.
(a) A real time comparison of VCA driving voltage, the position of the actuator’s piston, and the associated fluid flow waveform for an input sinusoidal waveform with a frequency of 2 Hz. (b) Phase and amplitude plots for driving voltage and piston position. (c) Phase and amplitude plots for the piston velocity and fluid flow waveform.