Table 4.
Ocular data of eligible and ineligible subjects in the BAM Study, mean ± standard deviation right eye, unless otherwise noted.
| Eligible (n = 49) |
Ineligible (n = 24) |
P-value | |
|---|---|---|---|
| Refractive Error (D) | |||
| Spherical Equivalent | −2.33 ± 1.03 | −1.64 ± 1.21 | .32 |
| J0 | −0.07 ± 0.18 | 0 ± 0.26 | .18 |
| J45 | −0.05 ± 0.18 | 0 ± 0.23 | .40 |
| Best Corrected LogMAR Visual Acuity | |||
| High Contrast Distance OD | −0.01 ± 0.06 | +0.02 ± 0.09 | .30 |
| High Contrast Distance OS | −0.02 ± 0.06 | +0.01 ± 0.07 | .09 |
| High Contrast Distance OU | −0.02 ± 0.07 | 0.00 ± 0.07 | .26 |
| Low Contrast Distance OU | +0.09 ± 0.07 | +0.12 ± 0.09 | .19 |
| High Contrast Near OU | −0.08 ± 0.07 | −0.05 ± 0.09 | .15 |
| Pupil Size (mm) | |||
| Photopic | 5.4 ± 0.6 | 5.3 ± 0.6 | .53 |
| Mesopic | 6.6 ± 0.6 | 6.5 ± 0.7 | .63 |
| Simulated Keratometry (D) | |||
| Steep Meridian | 44.05 ± 1.39 | Not measured | |
| Flat Meridian | 43.37 ± 1.32 | Not measured | |
| Biometry (mm) | |||
| Anterior Chamber Depth | 3.94 ± 0.21 | Not measured | |
| Lens Thickness | 3.32 ± 0.13 | Not measured | |
| Vitreous Chamber Depth | 17.13 ± 0.63 | Not measured | |
| Axial Length | 24.39 ± 0.62 | Not measured |
P-value indicates the comparison between eligible and ineligible subjects.
J0 = with- and against-the-rule astigmatism components; J45 = oblique astigmatism components; OD = right eye; OS = left eye; OU = both eyes; D = diopter; mm = millimeter