Skip to main content
. 2019 May 7;19:77. doi: 10.1186/s12903-019-0779-4

Table 1.

Characteristics of included studies

Author(year) Country Sample size Mean age (range) Study type The position of implant Type of implant and surface Bone condition Performed analysis Evaluation time
Abohabib(2018) Egypt 15 20.9 ± 3.4 Split mouth Between the maxillary second premolar and first molar buccally AbsoAnchor orthodontic mini-implants (AbsoAnchor, Dentos, Daegu, Korea) with a diameter of 1.5 mm and a length of 8 mm NR RFA in Hertz Immediately and 1, 2, 3, 4, 6, 8, 10 weeks later
Mandić(2015) Serbia 12 61.28(55–75) Split mouth Premolar and/or molar maxillary regions Self-tapping BlueSky® implants(Bredent, Germany) with a diameter of 4 mm and a length of 10 mm Type D3 and D4 RFA in ISQ Immediately and 1, 2, 3, 4, 5, 6 weeks later
Karaca(2018) Turkey 25 51.2 ± 2.3(36–64) NR Posterior mandible DTI Implant Systems(Istanbul, Turkey) with a diameter of 4 or 4.5 mm and a length of 10 mm Minimum 12 mm above the mandibular canal and minimum 5.0 mm in width RFA in ISQ Immediately and 6 months later
García-Morales (2012) Brazil 8 36(20–55) Split mouth Posterior mandible XiVE-S implants(Dentsply Friadent, Mannheim, Germany) with a diameter of 3.8 mm and a length of 11 mm Type 2 RFA in ISQ Immediately,10 days and 3,6,9,12 weeks later
Memarian(2018) Iran 12 NR Split mouth Mandible(one in the midline and the other two at the left and right canine teeth positions) DIO implants (Korea) with resorbable blast media surface(invasive fungal infections-tissue level) Type 2 or 3 PTV Immediately and 3,4,8 weeks later
Ekizer(2016) Turkey 20 16.77 ± 1.41 (13.1–19) Split mouth Between the roots of maxillary first molars and second premolars Screw-shaped titanium orthodontic miniscrews with a diameter of 1.6 mm and a length of 8 mm NR RFA in ISQ Immediately and 1,2,3 months later
Gokmenoglu (2014) Turkey 15 LED:50.43 ± 9.25; C:45.87 ± 13.46 NR NR XiVE implants(Dentsply-Friadent, Mannheim, Germany) with a diameter of 3.8 (3.5–4.5)mm and a length of 11.0(11–11)mm in LED group, while with a diameter of 4.5((3.8–4.5)mm and a length of 11.0 (10.6–11.0)mm in control group Type 2 or 3 RFA in ISQ Immediately and 2,4,8,12 weeks later
Torkzaban(2017) Iran 19 Female:43
Male:40.8
NR Maxillary teeth Dio implants (Dio UF, Busan, Korea) with a diameter of 4 or 4.5 mm a length of 10 or 11.5 mm Type D3 and D4 RFA in ISQ Immediately,10 days and 3,6,12 weeks later

NR Not reported, RFA Resonant frequency analysis, PTV Periotest value, ISQ Implant stability quotient, C Control group