Published in final edited form as: Magn Reson Med. 2019 Apr 8;82(2):671–679. doi: 10.1002/mrm.27757

Table 4.

Reproducibility study measurements for Anisotropic Stiffness in kPa in one volunteer.

Scan1 Scan2 Scan3 Scan4
CC TH WM GM WB CC TH WM GM WB CC TH WM GM WB CC TH WM GM WB
C11 41.34 42.63 41.83 41.16 41.60 41.40 41.99 41.78 41.07 41.51 40.73 41.51 41.32 41.23 41.31 40.63 40.76 41.25 41.20 41.27
C22 52.62 50.31 45.79 46.94 46.26 53.75 51.71 45.34 45.45 45.40 51.20 46.10 44.53 44.55 44.56 52.80 51.80 44.78 46.67 45.59
C33 39.35 39.41 40.21 38.88 39.69 39.01 39.25 40.33 38.95 39.78 39.33 39.14 39.85 38.48 39.30 38.70 38.51 38.65 38.17 38.45
C44 6.65 6.57 6.47 6.46 6.46 6.60 6.43 6.38 6.39 6.39 6.52 6.42 6.38 6.33 6.36 6.51 6.37 6.32 6.32 6.32
C55 6.36 6.37 6.37 6.33 6.35 6.35 6.35 6.35 6.33 6.34 6.38 6.34 6.34 6.31 6.33 6.35 6.31 6.32 6.30 6.31
C66 6.81 6.76 6.63 6.65 6.64 6.49 6.60 6.50 6.49 6.50 6.49 6.62 6.48 6.51 6.50 6.38 6.54 6.47 6.50 6.48