Gray 2016.
Methods | Randomized controlled phase II | |
Participants | 56 participants with epithelial ovarian cancer | |
Interventions | Mucin 1 targeted dendritic cell vs standard of care | |
Outcomes | Progression‐free survival Overall survival Immune response |
|
Notes | ||
Risk of bias | ||
Bias | Authors' judgement | Support for judgement |
Random sequence generation (selection bias) | Low risk | Randomised trial |
Allocation concealment (selection bias) | Low risk | Randomised trial |
Blinding of participants and personnel (performance bias) All outcomes | Unclear risk | Information insufficient to permit judgement of ‘low risk’ or ‘high risk’ |
Blinding of outcome assessment (detection bias) All outcomes | Unclear risk | Information insufficient to permit judgement of ‘low risk’ or ‘high risk’ |
Incomplete outcome data (attrition bias) All outcomes | Unclear risk | Information insufficient to permit judgement of ‘low risk’ or ‘high risk’ |
Selective reporting (reporting bias) | Unclear risk | Information insufficient to permit judgement of ‘low risk’ or ‘high risk’ |
Other bias | Unclear risk | Information insufficient to permit judgement of ‘low risk’ or ‘high risk’ |