Geometric parameters of the beams printed with different speeds after the heating–cooling process.

Method Vp (mm/s) R1 (mm) R2 (mm) R3 (mm)
Experiments 20 8.20 21.00 29.50
40 9.60 12.40 29.10
70 10.70 5.90 28.50
FE Abaqus 20 8.31 21.20 29.55
40 9.75 12.34 29.00
70 10.57 6.08 28.60
In-house FE method 20 8.32 21.30 29.47
40 9.79 12.41 29.01
70 10.66 6.02 28.49