Study | Reason for exclusion |
---|---|
Akca 2013 | Not an RCT ‐ no specific details on method of allocation concealment, participant allocation, blinding of outcome assessment (detection bias) |
Al‐Zubeidi 2012a | Although this was an RCT on maxillary overdentures, more than 1 implant system was used on the same number of implants comparing different attachment systems |
Alsabeeha 2011 | Although this was an RCT, more than 1 implant system was used on the same number of implants (1 implant only) comparing different attachment systems |
Burns 2011 | Although this was an RCT using 1 implant system, different numbers of implants were used |
Cehreli 2010b | Although this was termed as an RCT, and the same number of implants was used, 2 different implant systems were used each with different attachment systems Note: authors advised that this was a retrospective study as see excluded from Esposito 2014 |
de Souza 2015 | Although this was an RCT, different implant systems were used, different numbers of implants were used with different attachment systems |
ELsyad 2012 | The RCT compares between 2 subtypes of bar attachment, and not between the main attachment system types (ball/stud, magnetic, telescopic or bar attachment systems) listed under Types of interventions |
Gotfredsen 2000 | The study did not use the same number of implants in all included participants. Study classified as an RCT, and even though termed a randomised prospective study, no details on method of random sequence generation, allocation concealment, participant allocation, or blinding of outcome assessment (detection bias) are included |
Karabuda 2008 | Not an RCT. The study also used different implant systems and different number of implants Note: see also excluded from Esposito 2014 |
Kleis 2010 | The study compares between 2 subtypes of the ball attachment, and not between the main attachment system types (ball/stud, magnetic, telescopic or bar attachment systems) listed under Types of interventions. Study classified as not an RCT although termed as a randomised, clinical prospective study |
Krennmair 2012 | The study compares between 2 subtypes of the ball attachment, and not between the main attachment system types (ball/stud, magnetic, telescopic or bar attachment systems) listed under Types of interventions. Study classified as not a cross‐over RCT with consecutive participants admitted to the study |
Krennmair 2006 | Not an RCT ‐ participants were randomised according to their clinician treating preference |
Krennmair 2008 | The study compares between 2 subtypes of the bar attachment, and not between the main attachment system types (ball/stud, magnetic, telescopic or bar attachment systems) listed under Types of interventions |
Krennmair 2012b | Not an RCT ‐ participants were randomly assigned according to clinician preference |
Kronstrom 2010 | Although this was an RCT and 1 implant system was used, different numbers of implants were used with only 1 attachment system |
Mericske‐Stern 2009 | Study classified as not a cross‐over RCT. The study compares between 2 subtypes of the bar attachment, and not between the main attachment system types (ball/stud, magnetic, telescopic or bar attachment systems) listed under Types of interventions |
Osman 2014 | Although this was an RCT ‐ it was on maxillary and mandibular overdentures with 1 implant system, using the same number of implants, there were titanium and zirconia implants used as well as only 1 attachment system used per jaw. Different attachment systems were not used in the maxilla and mandible for comparison |
Payne 2000b | Study not an RCT ‐ confirmed by author correspondence |
Slot 2013 | Although this was an RCT on maxillary overdentures and 1 implant system was used, different numbers of implants were used with only 1 attachment system |
Slot 2014 | Although this was an RCT on maxillary overdentures and 1 implant system was used, different numbers of implants were used with only 1 attachment system |
Walton 2009 | Although this was an RCT and 1 implant system was used, different numbers of implants were used with only 1 attachment system |
Watson 2002 | Although this was an RCT more than 1 implant system was used on the same number of implants comparing different attachment systems |
Wismeijer 1997 | Although this was an RCT using 1 implant system, different numbers of implants were used |
RCT = randomised controlled trial.