Ramet 2002.

Methods Single centre pilot randomized controlled trial
Participants 18 infants (aged > 4 weeks confirmed through author communication) receiving mechanical ventilation with pressure regulated volume control (PRVC)
Interventions Intervention: Automode (Siemens Servo 300) with automated switching from PRVC to volume support ventilation (VSV)
Control: manual (clinician) switching from PRVC to VSV
Outcomes Days of ventilation
Randomization to extubation in hours
Randomization to switching to VSV in hours
Comfort score on extubation
Notes Available in abstract form only
Risk of bias
Bias Authors' judgement Support for judgement
Random sequence generation (selection bias) Unclear risk Not reported and unable to obtain additional information
Allocation concealment (selection bias) Unclear risk Not reported and unable to obtain additional information
Incomplete outcome data (attrition bias) 
 All outcomes Unclear risk Unable to obtain additional information
Selective reporting (reporting bias) Unclear risk Unable to obtain information to make an assessment ‐ cannot find trial registration
Other bias Unclear risk Study only available in abstract form
Blinding of participants and personnel (performance bias) 
 All outcomes High risk Due to intervention type assumed personnel not blinded
Blinding of outcome assessment (detection bias) 
 All outcomes Unclear risk Unable to obtain information to make an assessment