Skip to main content
. 2019 May 16;7(1):coz020. doi: 10.1093/conphys/coz020

Table 5.

Linear mixed effect results for cod temperature-detrended heart rate’s relationship to sound measurements interacting (:) with day for 20 HRT (heart rate) tagged fish, excluding the behavioural data from the acoustic tags. Separate models were tested for each sound measurement

Response variable Covariate name Delta AICcnull Coefficient SE P
Heart rate Zero to peak sound pressure level (A0-pk) 9846 −0.240 0.030 <0.001
Zero to peak sound pressure level (A0-pk):day 0.077 0.014 <0.001
Zero to peak sound pressure level (P0-pk) 9852 −0.210 0.025 <0.001
Zero to peak sound pressure level (P0-pk):day 0.068 0.010 <0.001
AELcum 9875 −0.180 0.032 <0.001
AELcum:day 0.061 0.015 <0.001
AELsp 9879 −0.160 0.032 <0.001
AELsp:day 0.045 0.015 <0.01
Single pulse sound pressure level (SELsp) 9895 −0.140 0.024 <0.001
Single pulse sound pressure level (SELsp):day 0.040 0.100 <0.001
Cumulative pulse sound pressure level (SELsp) 9859 −0.220 0.027 <0.001
Cumulative pulse sound pressure level (SELsp):day 0.073 0.011 <0.001