Skip to main content
. 2019 May 16;5(5):e01720. doi: 10.1016/j.heliyon.2019.e01720

Table 4.

Comparison of electrochemical corrosion data for AISI 1020 carbon steel after 24 h of immersion packer fluid and glyoxal mixtures without and with 500 ppm of polyol phosphate. Influence of CO2.

CO2 Cinhibitor (ppm) Ecorr (mVSCE) icorr (μA cm−2) ba (mV dec−1) -bc (mV dec−1)
without 0 -736 ± 25 12.0 ± 2.8 70 ± 11 53 ± 11
with 0 -674 ± 13 15.9 ± 0.8 42 ± 8 43 ± 7
without 500 -758 ± 22 3.8 ± 0.9 109 ± 12 116 ± 11
with 500 -752 ± 18 5.2 ± 0.5 72 ± 11 44 ± 2