Table 4.
CCD Experimental design developed using Design Experts STAT EASE Software.
Std | A | B | C | D | Uricase activity (U/ml) |
|
---|---|---|---|---|---|---|
Observed | Predicted | |||||
1 | −1 | −1 | −1 | −1 | 15.83 | 15.23 |
2 | +1 | −1 | −1 | −1 | 6.99 | 6.57 |
3 | −1 | +1 | −1 | −1 | 15.68 | 15.23 |
4 | +1 | +1 | −1 | −1 | 10.69 | 10.22 |
5 | −1 | −1 | +1 | −1 | 11.17 | 10.66 |
6 | +1 | +1 | +1 | −1 | 6.85 | 7.25 |
7 | −1 | +1 | +1 | −1 | 5.2 | 5.33 |
8 | +1 | −1 | +1 | −1 | 15.45 | 15.23 |
9 | −1 | +1 | −1 | +1 | 10.85 | 10.13 |
10 | +1 | +1 | −1 | +1 | 6.11 | 6.38 |
11 | −1 | −1 | −1 | +1 | 10.98 | 12.19 |
12 | +1 | +1 | −1 | +1 | 7.35 | 6.71 |
13 | −1 | −1 | +1 | +1 | 15.63 | 15.23 |
14 | +1 | −1 | +1 | +1 | 15.75 | 15.23 |
15 | −1 | +1 | +1 | +1 | 13.9 | 14.15 |
16 | +1 | +1 | +1 | +1 | 10.72 | 12.09 |
17 | −1.68 | 0 | 0 | 0 | 14.14 | 14.59 |
18 | +1.68 | 0 | 0 | 0 | 5.6 | 5.94 |
19 | 0 | −1.68 | 0 | 0 | 11.24 | 11.16 |
20 | 0 | +1.68 | 0 | 0 | 4.16 | 4.10 |
21 | 0 | 0 | −1.68 | 0 | 10.11 | 9.44 |
22 | 0 | 0 | +1.68 | 0 | 9.5 | 9.09 |
23 | 0 | 0 | 0 | −1.68 | 14.42 | 15.23 |
24 | 0 | 0 | 0 | +1.68 | 4.73 | 5.24 |
25 | 0 | 0 | 0 | 0 | 7.35 | 7.86 |
26 | 0 | 0 | 0 | 0 | 5.38 | 5.84 |
27 | 0 | 0 | 0 | 0 | 9.84 | 9.17 |
28 | 0 | 0 | 0 | 0 | 10.83 | 11.95 |
29 | 0 | 0 | 0 | 0 | 7.33 | 6.71 |
30 | 0 | 0 | 0 | 0 | 12.125 | 11.78 |