Table 2. Maximum von Mises stress values recorded within the models (MPa).

Model Plunger diameter (mm) Plunger direction
Vertical Angular
Periodontal ligament simulation (+) 3 1.445 1.189
6 1.091 1.318
Periodontal ligament simulation (−) 3 1.445 1.189
6 1.084 1.318