TABLE 4:

Comparison of Enhancement Rate and Kinetic AUC at Each Time Point in the Ultrafast Acquisition

Time Point Malignant Benign p AUCa Interclass Correlation Coefficient

Enhancementrate
 C1 24 ± 35 3.7 ± 4.2 0.0074 0.69 ± 0.07 0.99 (0.98, 1.00)
 C2 104 ± 55 34 ± 36 <0.0001b 0.87 ± 0.04 0.94 (0.90, 0.97)
 C3 152 ± 52 69 ± 54 <0.0001b 0.87 ± 0.05 0.96 (0.93, 0.98)
 C4 165 ± 54 86 ± 56 <0.0001b 0.83 ± 0.05 0.95 (0.92, 0.97)
 C5 172 ± 58 99 ± 55 <0.0001b 0.81 ± 0.05 0.95 (0.91, 0.97)
 C6 174 ± 49 109 ± 57 <0.0001b 0.79 ± 0.06 0.93 (0.88, 0.96)
Kinetic AUC
 C1 97 ± 129 21 ± 29 0.0065 0.69 ± 0.07 0.96 (0.94, 0.98)
 C2 544 ± 388 151 ± 146 <0.0001b 0.88 ± 0.04 0.96 (0.93, 0.97)
 C3 1466 ± 698 520 ± 456 <0.0001b 0.89 ± 0.04 0.92(0.87, 0.95)
 C4 2609 ± 1018 1079 ± 841 <0.0001b 0.87 ± 0.04 0.90 (0.84, 0.94)
 C5 3825 ± 1373 1746 ± 1235 <0.0001b 0.86 ± 0.05 0.88 (0.80, 0.93)
 C6 5071 ± 1724 2495 ± 1630 <0.0001b 0.85 ± 0.05 0.87 (0.78, 0.92)

Note—Values in parentheses are minimum and maximum.

a

AUC ± standard error.

b

Statistically significant according to Bonferroni correction of 21 multiple comparisons (critical value, α = 0.0024).