Skip to main content
. 2019 May 14;2019:7472039. doi: 10.1155/2019/7472039

Table 1.

Knee joint biomechanical gait data classification-related studies.

Study Pathology Population Biomechanical variables Data acquisition Feature Ext/select Classification Acc
[64] ACL 20 ACL
26 injured knees
EMG PDP 11/23 minicomputer Fourier transform K-means
[51] OA 50 OA
63 AS
Spatiotemporal data
Kinematics
Kinetics
Optoelectronic measurement system
Force plate
Global rep.
PCA
LDA 94%
[38] OA 35 OA
107 AS
Kinematics 3D knee analyzer Local rep. ANOVA
[39] OA 12 OA
7 AS
Acceleration data
Kinematics
Kinetics
Vicon motion analysis system
Force sensor integrated treadmill triaxial gyroscopes and accelerometers
Local rep. LDA 87.9%
[40] OA 15 OA
15 AS
Spatiotemporal data
Kinematics
Kinetics
Optoelectronic measurement system
Force plate
Local rep. DST 96.7%
[41] OA 20 OA
25 AS
Spatiotemporal data
Kinematics
Kinetics
Optoelectronic measurement system
Force plate
Local rep. DST
[74] OA 110OA
91 AS
Spatiotemporal data
Kinematics
Kinetics
Vicon motion analysis system MLP 98.5%
[52] OA 50OA
63AS
Kinematics
Kinetics
Optoelectronic measurement system
Force plate
Global rep.
PCA
LDA 92%
[42] PFPS-OA 13PFPS
5OA
20 PKR
Kinetics Kistler force platform Local rep.
Hill-climbing algorithm
SVM 85-92%
[69] OA 11 OA
12 AS
Spatiotemporal data Vicon motion analysis system
GAITRite system
Hill-climbing algorithm SVM 94.2%
[53] OA 20 OA
22 AS
Kinematics
Kinetics
Optoelectronic measurement system
Force plate
Global rep.
PCA
DST 97.62%
[60] OA 26OA
16AS
Kinetics Kistler force platforms Global representation
WT
NN 91%
[59] OA 26 OA
16 AS
Kinetics Kistler force platforms integrated to an ADAL treadmill Global rep.
WT
NNC 90%
[68] OA 11 OA
12 AS
Spatiotemporal data Vicon motion analysis system
GAITRite system
Hill-climbing algorithm SVM 88.89%
[70] OA 24 OA
12 AS
Kinetics Bertec platform Wavelet packet based on the Fuz-Coc DT-SVM 93.44%
[37] OA 30 OA
14 AS
Kinematics KneeKG Local rep.
Global rep.
SVD 77.27%
93.18%
[61] ACL 29 ACL
15 AS
Kinematics
Kinetics
ADAL treadmill
Vicon motion analysis system
Global rep.
WT
NNC 83.2%
[49] OA 30 OA
14 AS
Kinematics KneeKG Global rep. SVD 93.1%
[56] ACL-R 6 ACL-R
10 AS
Kinematics Four cameras motion analysis system (Innovision) Global rep.
PCA
LR 93.75%
[43] OA 18 KS
20 non-KS
Kinematics KneeKG Local rep. Student's t-test
[57] AS 111 AS Kinematics KneeKG Global rep.
PCA
Discriminant model based on PCs' sign
[66] OA 2,900 OA Spatiotemporal data Computerized walking mat CART 89.5%–90.8%
[67] OA 2,911 OA Spatiotemporal data Computerized walking mat CART 89.5%–90.8%
[72] OA 47 OA
133 AS
Kinetics Kistler force plates Probabilistic PCA Bayes classifier 82.62%
[73] OA 25 KS
25 non-KS
29 OA
Kinematics KneeKG Bayes classifier
[46] OA 44 S
40 non-S
Kinematics KneeKG Local rep. CART 84.7%
[48] OA 100 OA Kinematics KneeKG Local rep. RTs 88%
[71] ACL 7 ACL
7 AS
Kinematics Vicon motion analysis system PCA SVM 100%
[47] OA 100 OA
40 AS
Kinematics KneeKG Local rep. RTs 85%
[65] AS 165 AS Kinematics KneeKG Isometric mapping DBSCAN algorithm
[62] OA 63 OA Kinematics KneeKG WT Kohonen neural network 90.47%